Description
okogawa EJA530E Pressure Transmitter
EJA530E converts pressure into 4 ~ 20mADC current signal output, with rapid response, remote setting, self-diagnosis and other functions.Low power, FF field bus, PROFIBUS PA and other communication protocols, standard configuration through SIL 2 security certification.
For 1 to 5 V HART (Output signal code Q)
Three or four wire low power 1 to 5 V DC output with HART, linear or square root programmable. HART protocol are superimposed on the 1 to 5 V DC signal. Output range: 0.9 V to 5.4 V DC
Ambient Temperature Limits
−40 to 85°C (−40 to 185°F)
−30 to 80°C (−22 to 176°F) with LCD display
Process Temperature Limits
−40 to 120°C (−40 to 248°F)